- Supply Power.................................120,240,480 Volts
- Wattage.......................................3,5,9,17 Watts per foot
- Module Length...............................24 inches (*1)
- Maximum Circuit Length...................720 feet (*1)
- Maximum Operating Temperature.......400º F / 204º C
- Maximum Exposure Temperature.........450º F / 232º C (De-energized)
- Dielectric Strength...........................Spark Test 4000 VAC
- UL Approved
Construction:
Bus
Wire - 2/C #12 AWG tin coated stranded copper
2/C #12 AWG nickel plated stranded copper (optional)
Bus Insulation - FEP Teflon extruded jacket
Binder - FEP Teflon extruded in a figure-8 design
Heating Element - Nickel-Chromium resistive wire
Jacket - FEP Teflon extruded overall
Also Available:
Overbraids
of tinned or nickel plated copper and stainless steel
Overjackets
of PVC, TPE, Teflon* FEP, PFA or Tefzel*
Monitor wire
Custom constructions
Features:
FEP Teflon - Entire construction employs Dupont FEP Teflon which is unaffected by chemicals
and solvents that may cause rapid deterioration of other plastics and
all but the most expensive metal alloys. High resistance to moisture,
flame, and radiation is also realized.
Optional Nickel Plated Bus Wires - For maximum thermal and corrosion protection.
Constant Wattage - Uniform heat; wattage remains the same regardless of circuitlength.
Zone Modules - Hand soldered and inspected to maintain 100% contact with bus wires.
Cut to Length on Site - Parallel resistance type heater eliminates the need for inventories
of different size heaters.
Caution:
Type
M-T-FEP cable can be overlapped provided that the process temperature
is
less than 250°F.