Specifications:
- Supply Power...........................................120, 240, 480 - Volts
- Wattage...................................................3, 5, 9, 17 - Watts per Foot
- Module Length..........................................24 - Inches (*1)
- Maximum Circuit Length............................720 feet (*1)
- Continuous Operating
Temperature.............450º F / 232º C
- Maximum Exposure Temperature...............500º F / 260º C (De-energized)
- Dielectric Strength....................................Spark Test 4000 VAC
- UL Approved
Construction:
Buss Wire - 2/C #12 AWG tin coated stranded copper
2/C #12 AWG nickel plated stranded copper (optional)
Buss Insulation - PFA Teflon extruded jacket
Binder - PFA Teflon extruded in a figure-8 design
Heating Element - Nickel-Chromium resistive wire
Jacket - PFA Teflon extruded overall
Also Available:
Overbraids of tinned or nickel plated copper and stainless steel
Overjackets of PVC, TPE, Teflon* FEP, PFA or Tefzel*
Monitor wire
Custom constructions
Features:
PFA Teflon - Entire construction employs Dupont PFA Teflon which is unaffected by chemicals
and solvents that may cause rapid deterioration of other plastics and
all but the most expensive metal alloys. High resistance to moisture,
flame, and radiation is also realized.
Optional Nickel Plated Bus Wires - or maximum thermal and corrosion protection.
Constant Wattage - Uniform heat; wattage remains the same regardless of circuit length.
Zone Modules - Hand
soldered and inspected to maintain 100% contact with bus wires.
Cut to Length on Site - Parallel resistance type heater eliminates the need for inventories of different size heaters.
Caution:
Type
M-T-PFA cable can be overlapped provided that the process temperature
is
less than 310°F.
*1-
Depending on the Voltage and Wattage Specified
|